- Overview
- How it works
- Key Features
- Key Benefits
 |
Why limit your PACS/RIS
to just DICOM images?
Why not add more clarity to your DICOM studies with reports, comments, additional information & other non-DICOM data?
What is Phoenix ?
Phonix is a Windows based multi-purpose DICOM converter that converts anything from non-DICOM images, JPG images, cine loops, scanned documents, digitized medical films to DICOM format and push it to a PACS server. Radiologists will therefore be able to query info on existing patients, access critical data including referral notes and reports alongside DICOM images adding more accuracy, efficiency and confidence to diagnose. |
- Add new patient or select a patient by querying from a DICOM server or Worklist server.
- Capture from Non-DICOM modalities or Scan documents or Scan medical films or import JPG, BMP, DICOM files stored locally.
- Review and edit images.
- Select desired images/sequences and send to PACS.
|
- Query/Retrieve
Query and retrieve patient information from a DICOM server or a modality worklist server.
- View patient documents side-by-side with DICOM images
Accepts scanned physician reports, technical notes, etc from TWAIN compliant scanners.
- Convert JPG, BMP or PNG files to DICOM
Import non-DICOM images including JPG, BMP, or PNG files that are stored locally.
- Push DICOM images stored outside the PACS
Import DICOM files stored locally and push to PACS.
- Edit DICOM header information
Import DICOM files from anywhere and edit selected header information prior to sending.
- Temporary local storage of converted DICOM files
Store converted DICOM images temporarily when the network is down and you are unable to push images to PACS server.
- Import images from TWAIN complaint digital cameras
Connect twain complaint cameras directly to the system and import all medical images stored.
- Auto generate study and series UIDs
Easy workflow to reduce manual intervention.
- Attach images to a particular study already on your PACS
Query from a particular DICOM server, select the patient to which you want to add the converted DICOM images.
- Accepts scanned films from film digitizers
Interfaces with Vidar film digitizer to accept scanned films.
- Image review tools – Zoom, pan, line, arrow, text, contrast, brightness, etc.
Manipulate images before sending it to PACS server.
- Crop or de-skew images before pushing to PACS server
User can remove unwanted areas and correct scanning errors made, when documents are placed in a tilted position.
|
- Save the cost of upgrading a non-DICOM modality.
- Include non-imaging data by interfacing document scanners and film digitizers to a PACS environment.
- No separate workstation is required as it runs on standard windows based PC.
- Improve workflow efficiency by querying patient information from a DICOM server or a modality worklist server.
- System Requirements
- Screenshots
- Downloads
|
* Operating System :
Windows NT, 2000 and XP.
* Processing Power :
Pentium III 600 Mhz or Higher.
* Memory :
256 MB or more RAM.
* Hard Disk :
50 MB of Free Disk Space for application and image Files.
* Network Inferface :
Standard network connection to DICOM devices and RIS.
* Scanners :
Standard TWAIN compliant scanning devices.
|
|
|
|